Glenn Herbert wrote:You don't want the mass heater giving a lot of heat to the slab directly under it anyway; all that would do is heat the earth which will not help the house. Rather than a foot of foundation, just lay a series of bricks spaced a brick or so apart, with air channels between them to allow free air movement. Then warm air can move out and help heat the room instead of the slab.
Hi Glenn thanks for the reply. I didnt really explain well
enough. The slab sits on top of 30cm of styrofoam insulation and imbedded in it are under floor heating pipes which are designed for temperatures of up to 45c.
Your idea about the bricks spaced out under the Firebox is great. I would probably like to put a bigger slab of concrete on top of this in order to build the Firebox on something level.. Then space out the bricks underneath it to create the air gaps. Would standard bricks be ok for this purpose?