Sean Rauch

+ Follow
since Nov 03, 2013
Merit badge: bb list bbv list
For More
Winnipeg, Manitoba
Apples and Likes
Apples
Total received
In last 30 days
0
Forums and Threads

Recent posts by Sean Rauch

As always the debate about how Permi foams are rages on. The only thing I would add for the lay person is that yes EPS foam is not "the best" foam product on the market, however it is depending on your perspective and use probably your best bang for the buck product on the market.

Looking at their construction video, the major thing I would do differently is I would probably spray foam the foam joints at the inside to ensure that there is a consistent vapor barrier on the inside of the envelop that will allow the wood studs to still somewhat dry to the outside of the wall if necessary.
10 years ago
My wife and I are looking at building a second home in San Diego and I'd like it to be a high efficiency envelope. I know the climate is really temperate and in the target zone for sure. I'm thinking that in that area with a proper passive solar design we could get away without any air conditioning or heating? What kind of insulation profile are we looking at for this area?
10 years ago

Topher Belknap wrote:

Sean Rauch wrote:Few comments in red

Topher Belknap wrote: and replied in green
2) Air sealing (especially if you plan to run your house at positive pressure) is important, as you don't want to be pumping warm moist air into your walls where it will condense, and encourage rot.
If your less permeable barrier is to the inside of the wall this should be a non issue. Walls should breath to the outside.
A low-permeability barrier is all well and good, in the appropriate climates. But a) It doesn't do anything to reduce infiltration through holes, which are the vast majority of the air sealing failures. b) It is usually not something homeowners of existing homes have a lot of control over. (or perhaps more accurately, want to take control of) c) Drying to the outside is no substitute for not letting moisture into the walls in the first place, d) Is not a good idea in certain climates.



Thank You Kindly,
Topher



Sealing a wall either from both sides equally or more to the outside is a bad idea all round. Summer humidity should be fine because you won't have a dew point for the moisture to become liquid inside the wall system you want a certain amount of "acclimatization" between your wall and the outside conditions. Where things go sideways is when you have a less permeable surface on the exterior that can get cold enough for interior humidity to condense against during the winter. Winter is where you get humidity condensing and rotting out the inside of your wall system.

Sealing up holes should have zero effect on this one way or another.

If the owner's issue is not enough insulation overall then they will want to address insulation for the entire envelope, however that looks. If there is enough insulation and its just air leakage through services, windows, doors etc then seal up the holes, its a no brainier. Purposely having air move unrestricted into the wall system from inside the house is your worst case scenario.

10 years ago
Few comments in red

Topher Belknap wrote:
1) As others have said, insulation and air sealing is usually a better place to start.
Yes coupled with the addition of an HRV would also help keep things efficient, comfortable, and healthy
2) Air sealing (especially if you plan to run your house at positive pressure) is important, as you don't want to be pumping warm moist air into your walls where it will condense, and encourage rot.
If your less permeable barrier is to the inside of the wall this should be a non issue. Walls should breath to the outside.
4) Positive pressure is not a solution for infiltration. It just becomes exfiltration.
Indeed, why would you want your building to to do either?
5) You are going to want the woodstove when the sun isn't shining, so the solar heater won't be in service.
Yes, I've battled with this problem myself... How can I get solar gain at night? The only solution I know of is thermal mass (anti Knight flame suit on...)

Thank You Kindly,
Topher

10 years ago

Miles Flansburg wrote:Sean, are you looking for places to buy them or ideas on how to convert them into houses?



Hi Miles,

I"m looking for ideas mostly.
10 years ago
Hey all I'm trying to source out some good information on shipping containers as homes. We are batting around the idea of a live/work multi family building from containers. Anyone have some good sources of info? Specifically we are looking at insulated units.
10 years ago

Mike Cantrell wrote:

miles rose wrote:

Essentially, my idea is to gut the inside of a house down to the bricks, apply an interior layer of earthen plaster over the exposed bricks, and then to bring the straw bales INSIDE of the house to use as interior insulation, which would then be finished in a final layer of interior earthen plaster.

What do you guys think?

Thanks



Hi Miles, welcome to Permies!

I hope your project succeeds! As much as I'd like to see Detroit reborn as an artist community, I'd much rather see it reborn as a hub of cold-climate alternative building.

I spend some time looking at houses in Detroit (as well as the rest of lower Michigan), so here are a couple of important factors for your plan:

First, it sounds like you might be picturing these houses as having load-bearing brick walls. Almost none of them do. That practice was pretty much over before Detroit's building boom, so they'll almost all be brick veneer over stud framing. Seriously, I'd bet that 96% of the brick houses in the city are brick veneer and 99.5% of the houses available for auction. That's going to change your approach- now you've got to cut a 1.5"x3.5" notch in your bales every sixteen inches for the studs OR leave a 3.5" gap between your bales and your bricks. Neither of these is desirable.

The other thing is that the $500 houses are mostly built before the era of open floorplans. Your contemporary tract houses, not such a big deal if your turn an 18'x 26' living room into a 16'x24' living room. Still fine. But you turn a 10'x12' room into a 8'x10' room, and you'll regret it.

If it were me, I'd be heading in the direction of doubling the studs and deciding how to insulate a twice-as-large-as-usual cavity, whether with slipstraw or rock wool or something else.

Good luck!



If this is the case then it will be hard to retrofit the structure to be more inline with a high performance envelope. Structural brick is a lot easier to work around than veneer.

You're probably not going to like this but the first decision you need to make about your project is: How will you quantify performance?

-energy efficiency?
-living space?
-useful space?

Buildings are very much machines, how they serve you is entirely up to you.
10 years ago
Dale I like the enthusiasm but I gotta say if there is one rule we've learned over the last 50 years of building it's that encasing bio matter in a plastic bag is a recipe for failure. Once moisture starts to get in either through wicking, ambient humidity or just leaking the wood will start to rot and once it starts rotting in those circumstances it goes fast.

I personally really like non organic foundations because they are far more resistant to water than wood or the like.

Think about it your putting wood in an open, upturned bag. So one crack in the wood post over time from drying or pressure and you have a place for water to run. Same theory as why cordwood walls fail with time.
10 years ago
Think of interior thermal mass as a thermal flywheel. So whatever inputs you put into it will be carried at a more moderate level over more time in a more consistent way. So thermal mass doesn't have much direct effect on energy input levels but it is vital for passive moderation temperature.

You can do cool things like run heating/cooling lines through TM and use it as an awesome radiant heat source as well as heat sink.
10 years ago
Jay is right.

Only thing I would add to this is that the insulation value will drop considerable with time, so even if it isn't yet rotting it will be losing its ability to insulate quickly. Your basically starting on the back side of a bell curve as far as performance goes. Soo, in short order you will have lost much of the value and wasted a lot of time and energy even if it doesn't rot.
10 years ago