Jan. 26 almost 50 DEGREES and SUNNY !!! What better time to be in the
greenhouse / studio, fine tuning my
rmh, its 75 out there and other than a short test fire after surgery no fire since yesterday eavning. When I rebuilt my core this spring I went with a very long burn tunnel , 18" roof on an 8" system ... I did get temps steady at 800+ F. on the barrel top, even went over the 1000 F mark a few times... but I wasn't getting the temps that I could get last season with a cast core and... a 9" burn tunnel roof. So.. Today in a mere 4 hour surgery I removed 5" from the roof of the burn tunnel, now I will see if I like a 13" roof better. With the longer tunnel I was getting excessive combustion
ash left over, left unchecked it would have stalled the whole system. Test burn was only one charge of
wood with sopping wet clay and it went exceedingly well. Waiting for this eavning to give it 4-5 hour burn to really dry out and heat up. I just had to try pushing the envelope a little... cause you know... if you don't try you'll never know if you can...