Hybrid Masonry Boiler / Heater based on Shorty core

 
Posts: 5
Location: Northern Kentucky
3
solar rocket stoves homestead
  • Likes 4
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Hi folks! I'm about to start building an off-grid house, two stories with an open floor plan, and this is the masonry heater I've designed for it.

I've been working on this design for awhile, and I think it's workable. Now I'm looking for feedback. Please see the attached Sketchup file.

I have a few pictures of how it sits in the house. Most of the public areas (kitchen, living, loft) are in line-of-sight to the stove. But the bedrooms are not, they won't get much if any radiant heat from the brick.

To avoid cold bedrooms, I'm incorporating a water heat exchanger and a large storage tank, inside the masonry, connected by thermosiphon. This also allows me to store hot water from other sources such as solar, if I want to. I will have this tank atmospherically vented and run a second coil inside the storage tank to extract the heat for the bedrooms. This should alleviate safety concerns (no pressure = no boom-squish). I will have thermocouples to monitor water temps and bell temps at various points, not for safety but to help me learn how to operate this beast.

I was initially looking at a DSR2 for the heater core, but I like the looks of Shorty. So I redesigned to fit that instead. This is a 9" core or 230mm. I went with a sidewinder design so that the hottest outlet gases are aimed at the heat exchanger to the right. I haven't found the official core dimensions yet, so the core model I used was one posted by Peter here, and I scaled it up.

There are three bells (or four, depends on your point of view). The first bell has the core and the heat exchanger. This flows up the back into the second bell, above the first and containing the water tank. There is a third bell above this, which is really an extension of the second bell with a large shutter to close it off. This allows some variability in how much heat goes to the upstairs vs the downstairs. After this, the gases flow into a side bench (bell #3), then out the back to a normal stovepipe. From there it goes straight up, approximately 20 feet to the roof, and 5-6 feet above to clear the peak and provide draft.

ISA calculations:

Total ISA is 426 sq ft, or 39.6 sq m. I know that is far too large for a cold start, even with a tall chimney. A 9" core wants about 123 sq ft, and Shorty has been derated by Peter by 10%, putting us at 110 sq ft.

There is a bypass directly from the first bell into the stovepipe, which cuts the ISA to 104 sq ft, that should get things going.  There is a large shutter which disables the top of the second bell, which cuts the ISA to 354 sq ft. The heat exchanger in Bell #1 is 22 sq ft, and the tank in Bell #2 is 57 sq ft.

After all the reading I've done, the masonry is like a thermal battery - so the more you have, the more heat you can store. From what I've been told, as long as the stove is warm and drawing well, there's no hard limit to how many bells you can use to extract and store heat. With that in mind, I want it to be tall enough to reach the second floor and heat some of it directly, and I want the extra mass that the water tank will provide (about 2500 lbs), with the flexibility to pipe the hot water to other rooms that aren't directly seen by the heater.

I am very interested in your opinions! Please review and let me know what you think.

Filename: hybrid_boiler_heater.skp
Description: Sketchup file. I'm not sure on version compatibility, as this is downloaded from their web app, which is free.
File size: 372 Kbytes
first-floor.png
Here's the first floor layout.
Here's the first floor layout.
inside-view.png
Inside first floor view
Inside first floor view
upstairs.png
This part of the stove is at the second floor.
This part of the stove is at the second floor.
boiler-1.png
Overview, showing bells alongside finished view
Overview, showing bells alongside finished view
boiler-2.png
Rear with cutaway. Note the shutter in upper bell, sliding bypass valve to Bell 1.
Rear with cutaway. Note the shutter in upper bell, sliding bypass valve to Bell 1.
boiler-3.png
Bottom view. Floor exit rear right Bell 1 to Bell 2. Return gases in center, flows to bench left, then out stovepipe rear.
Bottom view. Floor exit rear right Bell 1 to Bell 2. Return gases in center, flows to bench left, then out stovepipe rear.
Boiler-4.png
Closeup of sidewinder Shorty core, exit aimed to the right, towards water heat exchanger.
Closeup of sidewinder Shorty core, exit aimed to the right, towards water heat exchanger.
Boiler-5.png
Bypass. Hard to see behind Shorty, so here's a closeup. Directly from Bell 1 to stovepipe.
Bypass. Hard to see behind Shorty, so here's a closeup. Directly from Bell 1 to stovepipe.
 
Posts: 556
Location: Sierra Nevada foothills, 350 m, USDA 8b, sunset zone 7
95
  • Likes 5
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
In theory, with separately  damped bells it may be possible, but I would recommend reading these threads first:

Help! My Rocket doesn't heat

Just to heat 1000 liters of water in your tank it will use at least 30 kg of wood - more than one batch in 230 mm system and with the assumption that combustion is perfect.

In this thread:

At Last. My RMH Is a Reality

user/builder removed just one brick shelf to notice improvements in the heating performance.


After edit:

The beauty of mass heaters is in their passive simplicity. Have you considered the following:
-downsizing the open area heater to let's say 7"
-and building another 7" heater in the middle of bedroom walls
?
Your house is probably custom design so you could add another chimney.
Two 7" heaters would have similar power as one 9".
It would simplify the things and provide better and more reliable heat to the bedrooms.
I would recommend to locate one of its sides on bathroom wall.
If I knew that I will be building masonry heaters I would add a second chimney to my house and definitely build the kitchen stove with a mini bell on the bathroom side.
In large houses in Europe it was normal to have one masonry heater per room.
It would help if you mentioned what type of construction the house will be and in what climatic zone it will be located.
 
rocket scientist
Posts: 6318
Location: latitude 47 N.W. montana zone 6A
3188
cat pig rocket stoves
  • Likes 5
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Hi Chris;
I have a Shorty core, she is awesome!
However, she is a very casual burner.
She is just as hot as the first-generation batchbox, but she is not screaming around your valley showing off and roaring.

The DSR versions although technical to build correctly, are roaring dragons
The first-generation batchboxes defined what a roaring dragon performs like.

Shorty takes off and just burns, no showboating, just a super clean burn.
Your water manifold might not get the blast of high heat that you are hoping for.
With her tapered riser, changing from 6 x6" to 6x9" and then hitting a roof and turning down slows down the movement of gasses.
Shorty is brand new, Peter and I are still learning how she flies and what it takes to make her happy (we like happy dragons)
Hence the 10% drop in ISA and the addition of a bypass

The finished plans on Shorty have not been compiled online yet.
Send a message to Peter, and he will provide you with the information you seek
 
Chris Saenz
Posts: 5
Location: Northern Kentucky
3
solar rocket stoves homestead
  • Likes 7
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Some more information would perhaps be helpful.

The house is being built off-grid in Northern Kentucky, we have relatively mild winters with low temperatures usually single digits for maybe a week or two per winter. Very rarely do we see below 0°F, it does happen but only for a day or two. The house is a two-story timber frame design with exterior insulation and an insulated basement made from ICFs. The floorplan is around 2600 sq ft not counting basement. We will be completely off-grid with PV solar, backed up by a diesel generator.

I have performed a manual J heat load calculation for the house design, using this excellent tool: https://loadcalc.net. The end result was 35,000 BTUs on a 10°F day, or approximately 10.25 kW. According to the calculator, a 230mm core will burn 21.6 kg of wood per load producing 79.2 kWh of heat. Three firings per day will be sufficient heat for all but the coldest days we have here. Most days will be around 20-30°F, which will cut our wood needs to perhaps two firings.

Another calculation I made, was the heat storage capacity, both of the water and the masonry. I calculate the total water held in the system to be 300 gallons / 1135 liters. The masonry on a stove this big will be in the neighborhood of 13,000 lbs / 6,000 kg. For operating temperatures, I will consider 63°F "cold" and 200°F "hot". Another way to think about it, 0% and 100% on my thermal battery.

With a temperature delta of 137, the heat storage capacity of the water is 100 kWh, and the heat storage capacity of the masonry is 872 kWh. From this I can draw a few conclusions.

- Even though the heat storage of the water is only 1/10 of the masonry, the ISA of the heat exchanger and tank are 2/10 of the total ISA. I would therefore expect the water to saturate with heat faster than the masonry. This is good, so that I can circulate out the water heat to other rooms, without overheating the masonry.

- Total heat storage around 1,000 kWh will carry us through approximately 4 days of 10°F  weather with no fires, from fully hot to stone cold. I never expect this to happen, we will obviously light fires as needed and maintain more moderate temperatures.

- If 2/10 of the output is directed to water, I can withdraw 16 kWh per firing for the bedrooms. This is roughly equivalent to two electric space heaters on a medium setting, which is fine for a well insulated house.

=================

To answer Thomas, I do not need a screaming fire from the core. I'd actually prefer a less intense heat to reach the heat exchanger so that it will last a long time. I'm more interested in the ability to hot refuel cleanly, which it appears Shorty does well. As you can see I will probably need to run multiple firings back to back at times.

I was originally considering a DSR2, and could be convinced to go back to that, if Shorty is not "ready".... There is some time yet before I'm ready to build, and the bell I have designed is flexible enough to make changes as needed. I will build it in a way that I can, with moderate effort, rebuild the core and service the heat exchanger.

================

To answer Cristobal,  I understand the volume of wood this will require to get up to temperature. By my calculation, it will take 12 firings from 63°F (cold) to 200°F (very hot). Once the house is warmed however it should only need one or two firings per day. Even still, a batch for this size core is 47 lbs, at least two armloads of wood. I have plenty of wood available and I'm used to burning a few cords per winter. I don't expect to heat a large house with twigs. I'm here for the comfortable heat more than the efficiency. But I do love how efficient these are!

In the first thread you link to it appears they didn't insulate the riser, causing incomplete combustion, used too small pipes for the water exchanger, and underestimated the wood required to heat it all up. The second thread indeed shows the utility of a design which can be modified after assembly.

I could build a second heater but I don't want to sacrifice the space, and I don't want to carry firewood back into bedrooms. In my view, instead of simplifying things it actually complicates the house construction, requires operating multiple heaters, and disrupts my floorplan. I am more willing to sacrifice space in the large open areas than in small bedrooms.

Additionally, this is not the only heat source I have in mind. I am leaving open the possibility to incorporate solar, geothermal, and CHP (water cooled generator), which means I need a common medium of exchange, ie water, to carry this heat to its destination. With water inside the masonry, I could actually back-feed heat from the other heat sources into the brick, extending time between firings and eliminating the need for other distribution systems like ductwork.

===============

Other concerns I have anticipated:

- Water leakage. Tanks do eventually corrode, plumbing leaks. Storing 300 gallons of hot water in your living room could be a liability. I will have an emergency drain at the base of the heater, the tank and heat ex will be stainless steel, and access panels will be placed appropriately to service the plumbing fittings.

- Domestic Hot Water. I don't actually intend to use this for DHW, although I could. I think we'll have sufficient solar PV capacity to just run the water heater directly on electric, with propane backup. I could change my mind here though.

- Cooling capacity. In the summertime, this large mass of brick will be a massive heatsink and will significantly contribute to cooling the house. I am looking at ground-source heat pumps for summertime A/C, but running cold water through the tank and heat ex should continually draw heat out of the bricks - condensation being the main issue and limitation to this approach.

- Window wall. Opposite this heater is a large south-facing wall containing the most windows anywhere in the house. During sunny days, the sun will warm the bricks, and during the nights I will close insulating curtains or shutters over them to keep the heat inside. In the summer, the reverse - curtains closed for the hottest hours of the day, and windows open at night to cool the bricks and the house down with fresh night air.
 
thomas rubino
rocket scientist
Posts: 6318
Location: latitude 47 N.W. montana zone 6A
3188
cat pig rocket stoves
  • Likes 6
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Hey Chris;
Any Batchbox design can be run as an extreme burner. I have four Batchboxes, and two of them are extreme burners.
I suggest writing to Peter and getting his opinion on your plans and what style of Batchbox he thinks would be most appropriate.

 
Chris Saenz
Posts: 5
Location: Northern Kentucky
3
solar rocket stoves homestead
  • Likes 5
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Thanks Thomas, I've sent him a message.
 
Rocket Scientist
Posts: 790
Location: Guernsey a small island near France.
299
  • Likes 8
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Tom, when you say extreme burning , I think you mean continues loading and I am not sure if that would remain a clean burning stove under EU regulation.
I guess Peter is the only one who might know ?
Generally speaking the stove needs to burn down to coals and even them must be carefully re loaded with small loads.
Maybe the shorty is fine with that but, from my own experience with the standard batch box, you can easily  get them to over-fuel and smoke.
Again this might not even be an issue for many folk but, it might be in a built up European location?
 
thomas rubino
rocket scientist
Posts: 6318
Location: latitude 47 N.W. montana zone 6A
3188
cat pig rocket stoves
  • Likes 9
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
Hi Fox;
Excellent points about regulations.
Other than the masonry stove regulations, that is a subject I never give much thought to.
In rural America, it is a non-issue.
Where I live my home is the only one not pumping out clouds of noxious smoke.
The two continually loaded batches (extreme burners) put out a white cloud of steam for a few moments after a reload and then return to heat shimmers.
Other than during a cold start, Shorty only releases small wisps of steam or nothing at all.
None of my stoves put out the black cloud of overburning or the damped down clouds of thick grey yucky that we commonly associate with wood stoves.
 
Chris Saenz
Posts: 5
Location: Northern Kentucky
3
solar rocket stoves homestead
  • Likes 8
  • Mark post as helpful
  • send pies
    Number of slices to send:
    Optional 'thank-you' note:
  • Quote
  • Report post to moderator
I have received a reply from Peter, and he indicates the ISA is grossly oversized, with not nearly small enough ISA in bypass mode. So, here are three things I've learned about oversizing (answering my previous question from here):

- You can indeed oversize bells with a bypass, but not by 3-4x.  You should not significantly exceed 125% of the nominal ISA.

- The nominal ISA for double bell systems should be reduced by 15%. The extra bell adds efficiency, which lowers the draw. It also changes gas flow directions, further reducing draw.

- ISA in bypass mode should be 1/3 or less of the nominal ISA to be effective. My incorrect understanding was anything less than 100% would be effective.

Additionally, Peter is not fond of the water heating aspect, it's adding too much complexity to the system. He's not the only one who's told me this build is too complicated. I do listen! So, I'm redesigning.

I'd rather be humble and redesign on paper, than wind up with several tons of masonry built that doesn't perform well.
 